Selected Grantee Publications
First-in-Human ImmunoPET Imaging of COVID-19 Convalescent Patients Using Dynamic Total-Body PET and a CD8-Targeted Minibody
Omidvari et al., Science Advances. 2023.
https://pubmed.ncbi.nlm.nih.gov/36993568/
Developing noninvasive methods for in vivo quantification of T cell distribution and kinetics is important because most T cells reside in the tissue. Investigators presented the first use of dynamic positron emission tomography (PET) and kinetic modeling for in vivo measurement of CD8+ T cell distribution in healthy individuals and COVID-19 patients. Kinetic modeling results aligned with the expected T cell trafficking effects. Tissue-to-blood ratios were consistent with modeled net influx rates and flow cytometry analysis. These results provide a promising platform for using dynamic PET to study the total-body immune response and memory. Supported by ORIP (S10OD018223) and NCI.
Using Mass Spectrometry Imaging to Map Fluxes Quantitatively in the Tumor Ecosystem
Schwaiger-Haber et al., Nature Communications. 2023.
https://pubmed.ncbi.nlm.nih.gov/37208361/
Mass spectrometry imaging (MSI) can be used to identify metabolic patterns within different microenvironments of tumors but has not been fully integrated into metabolomics workflows. Investigators developed an integrated approach by combining MSI, stable isotope labeling, and a spatial variant of Isotopologue Spectral Analysis to study metabolic pathways across the brains of mice harboring GL261 glioma, a mouse model for glioblastoma. This study reveals the importance of multiple anabolic pathways, including fatty acid elongation flux, in glioma. Supported by ORIP (R24OD024624).
Association of Age at Menopause and Hormone Therapy Use With Tau and β-Amyloid Positron Emission Tomography
Coughlan et al., JAMA Neurology. 2023.
https://pubmed.ncbi.nlm.nih.gov/37010830/
To understand the predominance (70%) of women among individuals with Alzheimer’s disease, the investigators studied regional tau and β-amyloid (Aβ) in relation to age at menopause and hormone therapy (HT) in postmenopausal women and age-matched men using positron emission tomography. The study demonstrated that females exhibited higher tau deposition compared with age-matched males, particularly in the setting of elevated Aβ; earlier age at menopause and late initiation of HT were associated with increased tau vulnerability. This study suggests female individuals with these conditions may be at higher risk of pathological burden. Supported by ORIP (S10OD025245), NIA, and NICHD.
In Vivo MRI Is Sensitive to Remyelination in a Nonhuman Primate Model of Multiple Sclerosis
Donadieu et al., eLife. 2023.
https://pubmed.ncbi.nlm.nih.gov/37083540/
Experimental autoimmune encephalomyelitis (EAE) in the common marmoset is a model for studying inflammatory demyelination in multiple sclerosis (MS). Researchers investigated the feasibility and sensitivity of magnetic resonance imaging (MRI) in characterizing remyelination, a crucial step to recover from MS. Investigators demonstrated that multisequence 7T MRI could detect spontaneous remyelination in marmoset EAE at high statistical sensitivity and specificity in vivo. This study suggests that in vivo MRI can be used for preclinical testing of therapeutic remyelinating agents for MS. Supported by ORIP (R21OD030163) and NINDS.
Characterizing a Photoacoustic and Fluorescence Imaging Platform for Preclinical Murine Longitudinal Studies
Thompson et al., Journal of Biomedical Optics . 2023.
https://pubmed.ncbi.nlm.nih.gov/36895414/
Preclinical studies using animal models require medical imaging technology with sufficient resolution and sensitivity for anatomical, functional, and molecular assessments. Photoacoustic (PA) tomography provides high resolution and specificity, and fluorescence (FL) molecular tomography provides high sensitivity; the combination of these imaging modalities capitalizes on their strengths and mitigates disadvantages. In this publication, the authors describe TriTom, a preclinical imaging system that integrates PA and FL. They characterized the PA spatial resolution, PA sensitivity, PA spectral accuracy, optical spatial resolution, and FL sensitivity of the platform and demonstrated anatomical imaging in mice. This report demonstrates TriTom’s suitability for biomedical imaging applications. Supported by ORIP (R43OD023029) and NCI.
Naturally Occurring Osteochondrosis Latens Lesions Identified by Quantitative and Morphological 10.5 T MRI in Pigs
Armstrong et al., Journal of Orthopaedic Research. 2023.
https://pubmed.ncbi.nlm.nih.gov/35716161/
Juvenile osteochondritis dissecans (JOCD) is a pediatric orthopedic disorder that is associated with pain and gait deficits. JOCD lesions form in the knee, elbow, and ankle joints and can progress to early-onset osteoarthritis. In this study, researchers used a noninvasive magnetic resonance imaging (MRI) method to identify naturally occurring lesions in intact knee and elbow joints of juvenile pigs. This work can be applied to noninvasive identification and monitoring of early JOCD lesions and determination of risk factors that contribute to their progression in children. Supported by ORIP (K01OD021293, T32OD010993), NIAMS, and NIBIB.
3D-Bioprinted Phantom With Human Skin Phototypes for Biomedical Optics
Yim et al., Advanced Materials. 2023.
https://onlinelibrary.wiley.com/doi/abs/10.1002/adma.202206385
Human skin offers important physical and immunological protection based on its makeup with diverse cell types, including melanocytes, and variations in skin phototypes controlled by melanin concentration have negatively affected many optic technologies and wearable health-tracking electronic devices. To mimic the effects of melanosome variation, investigators studied optical properties and photoacoustic signal of synthetic melanin to create a 3D bioprinting rendition of the human epidermal thin layers. The effect of skin phototypes on thin-layer skin imaging at different wavelengths was quantified. These data could serve as a benchmark calibration tool of light-mediated diagnostics toward clinical use and further underpin development of biomedical optics. Supported by ORIP (S10OD023527, S10OD021821).
Fluorescence-Based Sorting of Caenorhabditis elegans via Acoustofluidics
Zhang et al., Lab on a Chip. 2020.
The authors present an integrated acoustofluidic chip capable of identifying worms of interest based on expression of a fluorescent protein in a continuous flow and then separate them in a high-throughput manner. Utilizing planar fiber optics, their acoustofluidic device requires no temporary immobilization of worms for interrogation/detection, thereby improving the throughput. The device can sort worms of different developmental stages (L3 and L4 stage worms) at high throughput and accuracy. In their acoustofluidic chip, the time to complete the detection and sorting of one worm is only 50 ms, which outperforms nearly all existing microfluidics-based worm sorting devices. Supported by ORIP (R43OD024963), NIEHS, and NIDDK.